Applications running water slurry pump test trial
slurry pump unit adjusted after installation , you can test run , conditional user , you should first test run using water , slurry pump transport operating normally again , test steps are as follows :
1 , open the seal water and cooling water , the pressure is adjusted to a predetermined value
2 , close the outlet valve , the inlet valve is fully open
3 , open the water valve to the pump filled with water ( without water intrusion )
4, start the unit until after the normal speed , open the outlet pressure gauge , if the pressure is normal and stable , you can slowly open the outlet valve until it is fully opened or satisfy the conditions required so far.
slurry pump pump manufacturers WARNING: - Driving impeller trip will reverse , causing the top part axial crack !
- Do not burn fuel will cause bearing !
- The mechanical seal must first open the seal water drive, otherwise burn !
- With a load test , you should close the outlet valve of the pump, start
After completing gradually open the valve to prevent motor overload burned !